GX
Series Balances
Our
Revolutionary Super Hybrid Sensor (SHS) Technology improves response speed and
minimizes maintenance costs. Its unique design provides the fastest response
speed in its class- just 1 second! And if the time ever comes when the SHS needs
repair, you just replace one of three parts - There is no need to replace the
whole sensor! This translates to Minimum Maintenance Costs. an
additional benefit of our new SHS is that the GX automatically performs self
calibration using the internal mass when the balance detects ambient temperature
changes.
IP54
Splash Proof Keyboard and Display
Provides excellent protection from dust and spills.
Standard
RS-232C
Bi-directional communication with a PC or connects directly to a printer.
Display
Auto Power off Function
Display turns off after 10 minutes to inactivity (user-selectable)
Density
Calculation Mode
(optional
Density Determination Kit & glass breeze break)
Automatically calculates and displays the density measurement results.
Input the temperature of water
Input the liquid's density directly (Range: 0.0000-1.9999g/cm3)
GLP
GLP/GMP/ISO Compliance
Allows GLP or LIMS balance management by downloading the balance ID number and
data used to calibrate the balance. The
data can be output to A&D's AD-8121 Printer or a computer, indicating date,
time, balance ID number, serial number and calibration data.
Data
Memory Function
Format the Data Memory Function for |
200 sets of weighing date |
100 sets of weighing data with time & date |
50 SETS OF GLP Data - Time & Date, Calibration Data, ID number and
Serial Number |
20 sets of Unit weight of counting mode
Auto
Self Calibration
Automatically self-calibrates when an ambient temperature change is
detected
Standard
Under-hook
Ideal for density determination and weighing magnetic substances.
Time&
Date
Standard Time & Date Function complies with GLP and interval
Weighing in the Data Memory Function.
Interval
Time Setting
Weighing intervals of 2,5,10,30 seconds and 1, 2, 5, 10 minutes in the
Data Memory Function.
![]() Shown with optional breeze break |
Auto
Power on Function
Automatically powers up to the stand-by model when connected to an
appropriate power source
Large
Square Weighing Pan
Standard large square weighing pan on all models GX200/400/600: 5.03 x 5.03 inch
GX2000/4000/6100/8000: 6.49 x 6.49 inch.
Auto
Re-Zero Function
Re-Zeroes Automatically after data output
Multiple
Weighing Units & Programmable Unit
Uses Programmable or standard units of measure (g, ct, dwt, etc.
Front
Air Bubble Leveling
Easily check the balance's level from the front
Quick
Reference Card
A quick-refer4ence operating guide slides out from under the
balance
Specs for GX series
| Model | GX-200 | GX-400 | GX-600 | GX-2000 | GX-4000 | GX-6100 | GX-6000 | GX-8000 |
| Weighing Capacity | 210g | 410g | 610g | 2100g | 4100g | 6100g | 6100g | 8100g |
| Minimum weighing value | 0.0001g | 0.01g | 0.1g | |||||
| Repeatability | .001 g | 0.01 g | 0.1 g | |||||
| Decimal oz. | 7.40755
x 0.00005 |
14.46230
x 0.00005 |
21.51710
x 0.00005 |
74.0755
x 0.0005 |
144.623
x 0.0005 |
215.170
x 0.0005 |
215.170
x 0.005 |
285.720
x 0.005 |
| Troy ozt. | 6.75165
x 0.00005 |
13.18180
x 0.00005 |
19.61195
x 0.00005 |
67.5165
x 0.0005 |
131.8180
x 0.0005 |
196.1195
x 0.0005 |
196.120
x 0.005 |
260.420
x 0.0005 |
| Pennyweight dwt. | 135.033 x 0.001 | 263.636 x 0.001 | 392.239 x 0.001 | 1350.33 x 0.01 | 2636.36 x 0.01 | 3922.39 x 0.01 | 3922.4 x .01 | 5208.4 x 0.1 |
| Carat ct. | 1050.000 x 0.005 | 2050.000 x 0.005 | 3050 x 0.005 | 10500.00 x 0.05 | 20500.00 x 0.05 | 30500.00 x 0.05 | 30500.0 x 0.5 | 40500.0 x 0.5 |
| Momme mom. | 56.0000 x 0.0005 | 109.3335 x 0.0005 | 162.6665 x 0.0005 | 560.000 x 0.005 | 1093.335 x 0.005 | 1626.665 x 0.005 | 1626.65 x 0.05 | 2160.00 x 0.05 |
| Grain GN. | 3240.80 x 0.02 | 6327.26 x 0.02 | 9413.74 x 0.02 | 32408.0 x 0.2 | 63272.6 x 0.2 | 94137.4 x 0.2 | 94136.0 x 2 | 125002.0 x 2 |
| Pound lb. | 0.462970
x 0.000005 |
0.903895
x 0.000005 |
1..344820
x 0.000005 |
4.62970
x 0.00005 |
9.03895
x 0.00005 |
13.44820 x 0.00005 | 13.4480 x 0.0005 | 17.8575 x0.0005 |
| Pound/Ounce | 7.41 oz | 14.46 oz | 1 lb. 5.52 oz | 4lb. 10.08 oz | 9 lb. 0.62 oz. | 13 lb. 7.17 oz | 13 lb. 7.17 oz. | 17lb. 13.72 oz |
| Linearity | ±0.002 g | ±0.003 g | ±0.02 g | ±0.03 g | ±0.1 g | |||
| Stabilization time | Approx. 1 second | Approx. 1.5 second | Approx. 1 second | |||||
| Sensitivity drift (10c -30c/50f-86F) | 2 ppm/ C(When automatic self calibration is not used | 5ppm/C (auto-self calibration OFF) | ||||||
| Operating Environment | 5º C to 40º C ( 41º F to 104º F), 85% RH or less ( no condensation) | |||||||
| Sensing method | Super Hybrid Sensor (SHS ) *SHS: Patent issued and pending | |||||||
| Display type | Vacuum Fluorescent Display (VFD) | |||||||
| Display refresh rate | 5 times/second or 10 times/second | |||||||
| Counting mode | 0.001 g | 0.01 g | 0.1 | |||||
| Counting samples | 10, 25, 50, or 100 pieces | |||||||
| Percent mode | 0.100 g | 1.00 g | 10.0 g | |||||
| Standard interface | RS-232C with Windows Communication Tools (WinCT) | |||||||
| Weighing pan | 128 x 128 mm ( 5.03 x 5.03 inch) | 165 x 165 mm ( 6.49 x 6.49 inch) | ||||||
| Calibration | Motor-driven internal Calibration with SHS/ The internal mass is equal to (approximately ) 500 grams. | |||||||
| External dimensions | 210 (W) x 317 (D) x 86 (H) mm | |||||||
| AC adapter | Confirm that the adapter type is correct for the local voltage and power receptacle | |||||||
| Power consumption | Approx. 11 VA (supplied by AC adapter( | |||||||
| Net weight | Approx. 4.6 Kg | Approx. 5.1 Kg | ||||||
Call us for orders, prices, quotes and more info...
TEL.-(800) 257-6707
(562) 921-6707
FAX-(562) 921-0307
13321 Alondra Blvd. Santa Fe Springs CA. 90670