GX Series Balances
Our Revolutionary Super Hybrid Sensor (SHS) Technology improves response speed and minimizes maintenance costs. Its unique design provides the fastest response speed in its class- just 1 second! And if the time ever comes when the SHS needs repair, you just replace one of three parts - There is no need to replace the whole sensor!  This translates to Minimum Maintenance Costs.  an additional benefit of our new SHS is that the GX automatically performs self calibration using the internal mass when the balance detects ambient temperature changes.
IP54 Splash Proof Keyboard and Display 
Provides excellent protection from dust and spills.

Standard RS-232C

Bi-directional communication with a PC or connects directly to a printer.

Display Auto Power off Function

Display turns off after 10 minutes to inactivity (user-selectable)

Density Calculation Mode 
(optional Density Determination Kit & glass breeze break)
Automatically calculates and displays the density measurement results.
Input the temperature of water
Input the liquid's density directly (Range: 0.0000-1.9999g/cm3)

GLP  GLP/GMP/ISO Compliance 

Allows GLP or LIMS balance management by downloading the balance ID number and data used to calibrate the balance.  The data can be output to A&D's AD-8121 Printer or a computer, indicating date, time, balance ID number, serial number and calibration data.
Data Memory Function
Format the Data Memory Function for
| 200 sets of weighing date | 100 sets of weighing data with time & date | 50 SETS OF GLP Data - Time & Date, Calibration Data, ID number and Serial Number | 20 sets of Unit weight of counting mode
Auto Self Calibration
Automatically self-calibrates when an ambient temperature change is detected
Standard Under-hook
Ideal for density determination and weighing magnetic substances.
Time& Date    
Standard Time & Date Function complies with GLP and interval Weighing in the Data Memory Function.
Interval Time Setting
Weighing intervals of 2,5,10,30 seconds and 1, 2, 5, 10 minutes in the Data Memory Function.


Shown with optional
breeze break


Auto Power on Function
Automatically powers up to the stand-by model when connected to an appropriate power source
Large Square Weighing Pan
Standard large square weighing pan on all models GX200/400/600: 5.03 x 5.03 inch
GX2000/4000/6100/8000: 6.49 x 6.49 inch.
Auto Re-Zero Function
Re-Zeroes Automatically after data output
Multiple Weighing Units & Programmable Unit
Uses Programmable or standard units of measure (g, ct, dwt, etc.
Front Air Bubble Leveling
Easily check the balance's level from the front
Quick Reference Card
A quick-refer4ence operating guide slides out from under the balance 

Specs for GX series

Model GX-200 GX-400 GX-600 GX-2000 GX-4000 GX-6100 GX-6000 GX-8000
Weighing Capacity 210g 410g 610g 2100g 4100g 6100g 6100g 8100g
Minimum weighing value 0.0001g 0.01g 0.1g
Repeatability .001 g 0.01 g 0.1 g
Decimal oz. 7.40755 x
0.00005
14.46230 x
0.00005
21.51710 x
0.00005
74.0755 x
0.0005
144.623 x
0.0005
215.170 x
0.0005
215.170 x
0.005
285.720 x
0.005
Troy ozt. 6.75165 x
0.00005
13.18180 x
0.00005
19.61195 x
0.00005
67.5165 x
0.0005
131.8180 x
0.0005
196.1195 x
0.0005
196.120 x
0.005
260.420 x
0.0005
Pennyweight dwt. 135.033 x 0.001 263.636 x 0.001 392.239 x 0.001 1350.33 x 0.01 2636.36 x 0.01 3922.39 x 0.01 3922.4 x .01 5208.4 x 0.1
Carat ct. 1050.000 x 0.005 2050.000 x 0.005 3050 x 0.005 10500.00 x 0.05 20500.00 x 0.05 30500.00 x 0.05 30500.0 x 0.5 40500.0 x 0.5
Momme mom. 56.0000 x 0.0005 109.3335 x 0.0005 162.6665 x 0.0005 560.000 x 0.005 1093.335 x 0.005 1626.665 x 0.005 1626.65 x 0.05 2160.00 x 0.05
Grain GN. 3240.80 x 0.02 6327.26 x 0.02 9413.74 x 0.02 32408.0 x 0.2 63272.6 x 0.2 94137.4 x 0.2 94136.0 x 2 125002.0 x 2
Pound lb. 0.462970 x 
0.000005
0.903895 x
0.000005
1..344820 x
0.000005
4.62970 x
0.00005
9.03895 x
0.00005
13.44820 x 0.00005 13.4480 x 0.0005 17.8575 x0.0005
Pound/Ounce 7.41 oz 14.46 oz 1 lb. 5.52 oz 4lb. 10.08 oz 9 lb. 0.62 oz. 13 lb. 7.17 oz 13 lb. 7.17 oz. 17lb. 13.72 oz
Linearity ±0.002 g ±0.003 g ±0.02 g ±0.03 g ±0.1 g
Stabilization time  Approx. 1 second Approx. 1.5 second Approx. 1 second
Sensitivity drift (10c -30c/50f-86F) 2 ppm/ C(When automatic self calibration is not used 5ppm/C (auto-self calibration OFF)
Operating Environment 5º C to 40º C ( 41º F to 104º F), 85% RH or less ( no condensation)
Sensing method Super Hybrid Sensor (SHS ) *SHS: Patent issued and pending
Display type Vacuum Fluorescent Display (VFD)
Display refresh rate 5 times/second or 10 times/second
Counting mode 0.001 g 0.01 g 0.1
Counting samples 10, 25, 50, or 100 pieces 
Percent mode 0.100 g 1.00 g 10.0 g
Standard interface RS-232C with Windows Communication Tools (WinCT)
Weighing pan 128 x 128 mm ( 5.03 x 5.03 inch) 165 x 165 mm ( 6.49 x 6.49 inch)
Calibration Motor-driven internal Calibration with SHS/ The internal mass is equal to (approximately ) 500 grams.
External dimensions 210 (W) x 317 (D) x 86 (H) mm
AC adapter Confirm that the adapter type is correct for the local voltage and power receptacle
Power consumption Approx. 11 VA (supplied by AC adapter(
Net weight Approx. 4.6 Kg Approx. 5.1 Kg

Call us for orders, prices, quotes and more info... 
TEL.-(800) 257-6707   (562) 921-6707 
FAX-(562) 921-0307
13321 Alondra Blvd. Santa Fe Springs CA. 90670